WinNUPRATM

winnupr2.gif (1590 bytes)

horizontal rule

SOFTWARE ERROR NOTIFICATION

Product Name:

Version: Error Number:

WinNUPRA

All Versions WN21-08

 

Brief Description of Error:

NURESULT - The Uncertainty Analysis for an Equation produces wrong results, if not all Basic Events of the Equation can be matched with the Parameter File.  For Basic Events that can not be matched with a record in the Parameter File, the value from the BED File is used instead.  This search in the BED File does not work correctly.

 

Possible Effects on Results:

The Uncertainty Analysis produces wrong results, if basic events of the equation can not be matched with records in the Parameter File.

 

Problem Classification:

 

Editorial Error  

X

Software Anomaly  

 

Nonconformance  

 

Workaround Suggestions:

Make sure that all Basic Events are matched with records in the Parameter File.

 

Correction Status:

Fixed in SR-2 of 2.1.

 

Issued By:

  Date:

Dieter Spiegel

  06/15/2001

 

horizontal rule

WinNUPRA is a trademark of Scientech. All other products mentioned are registered trademarks or trademarks of their respective companies.