WinNUPRATM

winnupr2.gif (1590 bytes)

horizontal rule

SOFTWARE ERROR NOTIFICATION

Product Name:

Version: Error Number:

WinNUPRA

2.1 WN21-02

 

Brief Description of Error:

NUCALCU - In the OCL process, when a Pseudo Event (XCOM- Event) is created with a negative probability, the value for the XCOM- Event is mistakenly changed to 1.0, instead of 0.0.

 

Possible Effects on Results:

The XCOM- Event in the BED File has a value of 1.0 instead of 0.0.

 

Problem Classification:

 

Editorial Error  

X

Software Anomaly  

 

Nonconformance  

 

Workaround Suggestions:

No workaround.

 

Correction Status:

Fixed in SR-1 of 2.1.

 

Issued By:

  Date:

Dieter Spiegel

  04/30/2001

 

horizontal rule

WinNUPRA is a trademark of Scientech. All other products mentioned are registered trademarks or trademarks of their respective companies.
Copyright 2000-2011 Scientech All rights reserved.
Last modified: Wednesday October 05, 2011.