WinNUPRATM

winnupr2.gif (1590 bytes)

horizontal rule

SOFTWARE ERROR NOTIFICATION

Product Name:

Version: Error Number:

WinNUPRA

All Versions WN20-15

 

Brief Description of Error:

NURESULT - The 'Log' Button in the 'Selected Subclass of Events' dialog box of the Sensitivity Analysis can only be activated by clicking on the 'Recalculate' button.   By clicking the 'Apply' button, the 'Log' Button stays inactive.

 

Possible Effects on Results:

When using a Fixed Multiplier for a subclass of events in the Sensitivity Analysis, the results can not be written to a Log File.

 

Problem Classification:

 

Editorial Error  

X

Software Anomaly  

 

Nonconformance  

 

Workaround Suggestions:

Use the 'Change Probability' option first to activate the 'Log' Button.  Then you are able to write results for the 'Fixed Multiplier' option to a Log file.

 

Correction Status:

Fixed in SR-3 of 2.0.

 

Issued By:

  Date:

Dieter Spiegel

  03/01/2001

 

horizontal rule

WinNUPRA is a trademark of Scientech. All other products mentioned are registered trademarks or trademarks of their respective companies.
Copyright 2000-2011 Scientech All rights reserved.
Last modified: Wednesday October 05, 2011.