WinNUPRATM

winnupr2.gif (1590 bytes)

horizontal rule

SOFTWARE ERROR NOTIFICATION

Product Name:

Version: Error Number:

WinNUPRA

2.0(SR-2) WN20-13

 

Brief Description of Error:

NUETREE - When using the maximum 5 characters for the Initiating Event in an Event Tree with more than 99 Sequences, the OCL File resulting from this Event Tree is not correct.

This problem does exist in previous WinNUPRA Versions, but never had any consequences, since OCL Files with more than 99 sequences could not be processed (see Error WN20-10).

 

Possible Effects on Results:

Sequences with sequence numbers > 99 are incorrect in the OCL File.

 

Problem Classification:

 

Editorial Error  

X

Software Anomaly  

 

Nonconformance  

 

Workaround Suggestions:

Do not use more than 4 characters for the Initiating Event in Event Trees, or limit the number of sequences to 99.

 

Correction Status:

Fixed in SR-3 of 2.0.

 

Issued By:

  Date:

Dieter Spiegel

  02/20/2001

 