WinNUPRATM

winnupr2.gif (1590 bytes)

horizontal rule

SOFTWARE ERROR NOTIFICATION

Product Name:

Version: Error Number:

WinNUPRA

1.2, 2.0, 2.0 (SR-1) WN20-12

 

Brief Description of Error:

NUMNTAIN - When opening and saving more than one Parameter File at the same time in the Data Module, the matching pattern of all open Parameter Files is set to the Matching Pattern of the Parameter File that was opened last.

 

Possible Effects on Results:

The Matching Pattern of a Parameter File is changed when saving it.

 

Problem Classification:

 

Editorial Error  

X

Software Anomaly  

 

Nonconformance  

 

Workaround Suggestions:

Do not open more than one Parameter File at the same time in the Data Module.

 

Correction Status:

Fixed in SR-3 of 2.0.

 

Issued By:

  Date:

Dieter Spiegel

  01/29/2001

 

horizontal rule

WinNUPRA is a trademark of Scientech. All other products mentioned are registered trademarks or trademarks of their respective companies.
Copyright 2000-2011 Scientech All rights reserved.
Last modified: Wednesday October 05, 2011.