WinNUPRATM

winnupr2.gif (1590 bytes)

horizontal rule

SOFTWARE ERROR NOTIFICATION

Product Name:

Version: Error Number:

WinNUPRA

All WinNUPRA Versions WN052

 

Brief Description of Error:

NUFTREE - When creating a new Basic Event in a Fault Tree, the Parameter File is searched for this basic event.  In this search, a basic event with a complete match should always be chosen over a basic event with a partial match (match with only the most significant characters).  However, the search order in Parameter Files depends on the physical location of the basic event in the alphabetically sorted Parameter File.  The search is performed from the first record to the last record in the Parameter File.  Whether the basic event of a partial match is chosen, or the basic event of a complete match, depends on which one comes first.

 

Possible Effects on Results:

A basic event with a partial match (match with only the most significant characters) might be used instead of a basic event with a complete match.

 

Problem Classification:

 

Editorial Error  

X

Software Anomaly  

 

Nonconformance  

 

Workaround Suggestions:

No workaround.

 

Correction Status:

Fixed in SR-4.

 

Issued By:

  Date:

Dieter Spiegel

  09/14/99

 

horizontal rule

WinNUPRA is a trademark of Scientech. All other products mentioned are registered trademarks or trademarks of their respective companies.
Copyright 2000-2011 Scientech All rights reserved.
Last modified: Wednesday October 05, 2011.