WinNUPRATM

winnupr2.gif (1590 bytes)

horizontal rule

SOFTWARE ERROR NOTIFICATION

Product Name:

Version: Error Number:

WinNUPRA

1.2, 1.2 SR-1, 1.2 SR-2 WN049

 

Brief Description of Error:

NUCALCU - Some of the resulting Equations of a Merge Process (OCL Processing) are not correct, if Pseudo Events (XCOM-Events) are involved in the Merge Process, and those Pseudo Events are not in the BED File.

 

Possible Effects on Results:

Some of the resulting Equation Files are not correct.

 

Problem Classification:

 

Editorial Error  

X

Software Anomaly  

 

Nonconformance  

 

Workaround Suggestions:

Make sure that all XCOM-Events are in the BED File before running a Merge Process, or run the OCL process twice.

 

Correction Status:

Fixed in SR-3.

 

Issued By:

  Date:

Dieter Spiegel

  07/27/99

 