WinNUPRATM

winnupr2.gif (1590 bytes)

horizontal rule

SOFTWARE ERROR NOTIFICATION

Product Name:

Version: Error Number:

WinNUPRA

All WinNUPRA 3.1 WN31-01

 

Brief Description of Error:

NUFTREE - When adding a Basic Event in a Fault Tree the Basic Event Data is not correctly retrieved from the Parameter File (PRM).  When a Basic Event is added the Editor first looks for this event in the fault tree.  If it cannot be found it looks in the BED File.  If it is not in the BED file, it looks in the PRM file, using the 3 levels of Parameter matching.  The newly introduced 3. level is not working correctly.  As a result a Level 3 match might be used even though a Level 2 match exists.

 

Possible Effects on Results:

The data of the incorrect Parameter File record might be retrieved for a new Basic Event in the Fault Tree.

 

Problem Classification:

 

Editorial Error  

X

Software Anomaly  

 

Nonconformance  

 

Workaround Suggestions:

No workaround.

 

Correction Status:

Fixed in 3.1 SR-1.

 

Issued By:

  Date:

Dieter Spiegel

  06/15/2007

 

horizontal rule

WinNUPRA is a trademark of Scientech. All other products mentioned are registered trademarks or trademarks of their respective companies.
Copyright 2000-2011 Scientech All rights reserved.
Last modified: Wednesday October 05, 2011.